Attribute | 3EGF021805 | 3EGF021814 | 3EGF020664 |
Rated voltage (kV AC) | 25 | 25 | 25 |
Insulators | Composite | Composite | Composite |
Rated continuous current (kA) | 1.7 | 1.7 | 1.7 |
Creepage distance (mm) | 1590 | 1590 | 1590 |
Rated short-time withstand current (kA) | 40 | 40 | 40 |
Short circuit current duration (s) | 1 | 1 | 1 |
Mass (kg) | 47 | 37 | 31.6 |
Perfect modular integration
TracFeed® MTS has proven itself over decades for disconnecting and connecting feeder sections of the contact line. Thanks to its modular design, the mast disconnector can be customised and easily installed at feeder points and insulated overlaps. Not least due to the solid construction and the materials used, Rail Power Systems TracFeed® MTS disconnectors have a very long service life and low maintenance requirements.
Your advantages at a glance
- Customisable basic profile – depending on the installation situation
- Insulators for 3 kV, 15 kV and 25 kV
- Retrofitting of the earth contact
- Long service life – tested for at least 50,000 switching cycles
- Dirt- and water-repellent insulators
- Insulator with increased creepage distance
- Minimised risk of short circuits through implementation in accordance with the provisions of the Birds Directive
- Can be used under a wide range of climatic and operating conditions
- Manufactured and tested in accordance with DIN EN 50152-2
- Backwards compatibility for use in existing systems

TracFeed® MTS Mast disconnector line contact with composite insulators and main contacts:
- Baseplate
- Fixed switch area with composite insulator
- Mating contact (with contact fuse)
- Arcing horns
- Contact blade
- Movable switch area with composite insulator
- Plate
- Swivel base
- Contact blade of earth contact
- Earth contact
- Connection point for the earthing cable
Technical data
You will find a sample overview here of selected models for 15/25 kV rated voltage. TracFeed® MTS is also available with insulators for 3 kV.
Attribute | 3EGF021803 | 3EGF021813 | 3EGF021021 |
Rated voltage (kV AC) | 25 | 25 | 25 |
Insulators | Composite | Composite | Composite |
Rated continuous current (kA) | 1.7 | 1.7 | 1.7 |
Creepage distance (mm) | 1590 | 1590 | 1590 |
Rated short-time withstand current (kA) | 40 | 40 | 40 |
Short circuit current duration (s) | 1 | 1 | 1 |
Mass (kg) | 38 | 29.5 | 31.6 |
Attribute | 3EGF021884 | 3EGF021020 |
Rated voltage (kV AC) | 25 | 25 |
Insulators | Composite | Composite |
Creepage distance (mm) | 1590 | 1590 |
Rated short-time withstand current (kA) | 40 | 40 |
Short circuit current duration (s) | 1 | 1 |
Mass (kg) | 27 | 28.2 |
Use in systems for automatic earthing of rail systems (e.g. TracFeed® AEA/TracFeed® OLSP)
The product in use
Your solution from a single source
Rail Power Systems is your systems provider with over 130 years of experience. From product to the associated components to installation, commissioning and maintenance on the track, we can provide you with the entire package on request. Our solutions are approved in numerous countries by system operators in local and long-distance transport and have proven themselves in decades of use under a wide variety of conditions. Feel free to contact us for more information. We are there for you all the way from planning to operation.
How can we help you?